Chlorine Dioxide (ClO₂) Sensor
Real-Time Chlorine Dioxide Monitoring Sensor for Safer Environments
Chlorine Dioxide (ClO₂) is a yellow-green gas known for its strong oxidizing properties. It is widely used in water treatment, pulp bleaching, and disinfection processes. However, at even low concentrations, ClO₂ can be harmful to human health and corrosive to materials. Accurate monitoring is essential for worker safety, equipment protection, and regulatory compliance. Oizom’s Chlorine Dioxide sensor provides real-time and precise measurement, even at trace levels. Designed for industrial use, it ensures long-term performance across demanding conditions and integrates easily into Oizom’s fixed and mobile air quality monitoring systems.
Oizom’s ClO₂ sensor operates on electrochemical sensing technology, where Chlorine Dioxide molecules react at the electrode surface, producing a microcurrent. This current is directly proportional to the ClO₂ concentration in the air. With a detection range of 0–1 ppm and a response time of 2-5 minutes, the sensor is ideal for critical environments where fast detection and high sensitivity are required. Its linearity and resolution make it suitable for real-time emission tracking and workplace exposure monitoring.
Built on the OGS (Oizom Gas Sensor) architecture, the ClO₂ sensor is engineered for durability, accuracy, and minimal drift. The sensor offers linear output up to 1 ppm and maintains stability across a wide temperature and humidity range. With its compact and robust housing, the sensor withstands harsh industrial environments and ensures long-term performance with minimal maintenance. It integrates seamlessly into our monitoring solutions, making it suitable for both fixed and mobile monitors, including confined spaces and open processing units.
The OGS design emphasizes selectivity, reducing cross-sensitivity, which helps ensure more reliable ClO₂ data. This makes the sensor reliable for continuous monitoring in various sectors.
The Oizom ClO₂ sensor is calibrated with various methods to ensure reliable baseline performance. For ongoing accuracy, the sensor is calibrated using certified ClO₂ calibration gas. This helps correct environmental drift and adapt to site-specific conditions.
The sensor also goes through colocation calibration, where it is deployed alongside a high-accuracy reference analyzer to fine-tune readings under real-world conditions. These calibration processes ensure the sensor delivers consistent and precise data throughout its lifespan, especially in high-exposure or dynamic environments.
OZCLO2_1
Range (ppm): 0-1 ppm
Resolution (ppm): 0.05 ppm
Min. Det.(ppm): 0.05 ppm
Drift: < 2% signal/month
Sensor Life: 2 years
Water Treatment Plants
Chlorine Dioxide is widely used for disinfecting drinking water and treating wastewater. Continuous monitoring ensures proper dosing and helps prevent overexposure for operators working near treatment units. Oizom’s ClO₂ sensor offers real-time data to maintain safety and operational control.
Pulp and Paper Industry
ClO₂ is a key bleaching agent in paper production. Its release during chemical processing can pose health risks and cause corrosion. Installing Oizom’s ClO₂ sensor enables safe monitoring and early leak detection, minimizing downtime and improving workplace safety.
Food and Beverage Processing
Chlorine Dioxide is used for sterilizing equipment and surfaces. Accurate monitoring ensures the gas remains within safe limits, protecting workers from exposure while maintaining hygiene standards. The sensor supports compliance with food safety norms.
Pharmaceutical Manufacturing
ClO₂ is used for air and surface disinfection in cleanroom environments. Oizom’s sensor helps maintain proper exposure levels, supporting strict process controls without compromising safety or regulatory requirements.
Industrial Hygiene and Safety Audits
For safety officers conducting environmental audits, Oizom’s portable ClO₂ sensor provides reliable on-site air quality assessments. This helps evaluate exposure levels, identify risks, and implement corrective actions.
Looking for Air Quality Monitoring Solution for your Project?
Schedule a call with our team of experts and get a customised solution for your air quality monitoring requirement.
Frequently Asked Questions (FAQs)
BTEX stands for Benzene, Toluene, Ethylbenzene, and Xylene, common volatile organic compounds found in industrial emissions and fuels.
These compounds are toxic and harmful to human health. Monitoring helps detect exposure early and ensures compliance with safety regulations.
It uses a photoionization detector (PID) that ionizes VOCs with UV light and measures the resulting electric signal.
It delivers 90% of the reading in less than 2 minutes, making it ideal for real-time monitoring.
Oizom’s sensor combines high sensitivity with rugged design. It delivers real-time data, is easy to integrate, and works reliably in extreme outdoor conditions, ideal for both industrial and ambient monitoring.
Yes, it’s built with a durable body and works well in extreme temperatures and high humidity.
The sensor is enclosed in a weather-resistant stainless steel housing. While it’s designed for outdoor use, proper housing or enclosures are recommended for long-term exposure to rain or direct splash.